Signal hygiene and comfort. None of these make music more exciting — they prevent it from being worse or more tiring.

TIP

Auto Gain and the fatigue filter both change the dynamics the artist chose. Use them for a purpose (shuffling a library, long sessions) rather than by default.

DC Filter ​

Removes DC offset: a constant bias in the waveform that wastes headroom and can produce clicks.

Parameters ​

ParameterRangeDefaultWhat it does
alpha0 – 0.10.02Filter coefficient. Higher = cutoff closer to DC, less low-frequency loss
Bass onlyon / offonOn = correct only the low band; off = correct the full spectrum

Leave Bass only on

Correcting the full spectrum means high-passing everything, which is a much bigger change than most people intend — it will thin out the sub-bass. Bass-only splits at 250/150 Hz and corrects just the region where DC offset actually lives.

DC offset is usually caused by a fault in the source: broken encoder, bad analog capture, or intentional asymmetry. If you need this effect constantly, the files are the problem, not the playback.

Auto Gain ​

One switch, no parameters. Monitors program loudness and normalizes gain toward a fixed target (internally 0.6 amplitude, gain limited to 0.1× – 2.0×).

Use it when you shuffle across a library with wildly different mastering levels. Do not use it when you are critically listening — a loudness normalizer is by definition changing the dynamics the artist chose.

Auto Gain vs. Compressor

Auto Gain works over seconds (song-to-song consistency). The Compressor works over milliseconds (musical dynamics). They solve different problems and are usually used together, not instead of each other.

Acoustic Fatigue Relief ​

Targeted attenuation of exactly the bands that make long listening sessions exhausting. Not a tone control — a comfort feature.

Parameters ​

ParameterRangeDefaultWhat it does
StrengthLight / Medium / StrongMediumSelects one of three fixed EQ curves

What each strength does ​

BandCharacterLightMediumStrong
3.15 kHz (Q 8)Human hearing's most sensitive region−9 dB−18 dB−26 dB
8 kHz (Q 8)Ear-canal resonance−14 dB−28 dB−40 dB
Above 16 kHzHigh shelf−7 dB−14 dB−20 dB
Below 200 HzLow shelf0 dB−4 dB−6 dB

Strong is very strong

−40 dB at 8 kHz removes essentially all of that band. Use Strong only if you are genuinely experiencing fatigue or have a specific sensitivity; Medium is already a substantial change that most listeners will notice immediately.

This is one of the few effects where the "correct" setting is a medical/comfort decision rather than an aesthetic one. If Light sounds thin, you probably do not need this effect at all.

Dither ​

Noise shaping applied at the final quantization step. Irrelevant at float precision, essential when the output is 16-bit.

Parameters ​

ParameterRangeDefaultWhat it does
TypeNone / RPDF / TPDF / Noise-shapedTPDFNoise distribution added before quantization
Shaping curveFlat / Weighted / P1 / P2 / P3WeightedOnly used by the Noise-shaped type

Types ​

TypeCharacterWhen to use
NoneNo ditherEffectively never — use if you are testing
RPDFRectangular, simplestNot recommended: adds noise without removing distortion
TPDFTriangular, standardThe default and the AES recommendation
Noise-shapedMoves noise out of the sensitive 2–6 kHz bandWhen you want the lowest perceived noise floor

Shaping curves ​

Weighted is psychoacoustically weighted and is the sensible default. P1 / P2 / P3 are progressively more aggressive POW-r style curves — they push more noise into the very high frequencies, which is fine on good systems and risky on anything with a tweeter that misbehaves.

When to turn this on

If you listen to 16-bit output (which is the default), leaving TPDF on is technically correct and audibly free. If you are testing other effects, turn it off — dither adds a small amount of noise that makes quiet passages harder to evaluate.